LinkSwitch-HP combines primary-side regulation and an integrated high-voltage MOSFET for constant-voltage flyback supplies. Subfamily selection matters: the official description distinguishes the fast-transient LNK666x option and different switch-voltage classes.
LNK677x uses a 725 V MOSFET, while LNK676x and LNK666x use 650 V devices. Review reflected voltage, clamp behavior and line excursions with the actual power-stage design; switch voltage is not an AC-input rating.
Protection can be configured for latching or hysteretic behavior, and shutdown delay is programmable. Preserve those choices when replacing a device in equipment where automatic recovery and operator reset have different consequences.
Key Features
- Fast-transient optionLNK666x
- Switch classes650 V or 725 V by subfamily
- Recovery behaviorCheck configured protection and delay
Target Applications
- Primary-side regulated appliance supplies
Compare LinkSwitch-HP Variants
Comparison of 4 selected variants from Power Integrations
| Parameter | LNK6776K-TL | LNK6666K-TL | LNK6776K | LNK6666K |
|---|---|---|---|---|
| Package / Case | 12-BESOP (0.350", 8.89mm Width), 11 Leads, Exposed Pad | 12-BESOP (0.350", 8.89mm Width), 11 Leads, Exposed Pad | eSOP-12B | eSOP-12B |
| Max Operating Temp | + 125 C | + 125 C | 150 °C | 150 °C |
| Min Operating Temp | - 40 C | - 40 C | -40 °C | -40 °C |
| Operating Temperature | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) |
| Auto Restart and Overvoltage Response | - | - | Auto-restart, Latch Off | Auto-restart, Latch Off |
| Availability | - | - | 现货 | 预售 |
| Breakdown Voltage | - | - | 725 V | 650 V |
| Control Features | - | - | Selectable Current Limit, Frequency Jittering, Soft Start, Auto-Restart/Latching Fault Response, On/Off Control | Selectable Current Limit, Frequency Jittering, Soft Start, Auto-Restart/Latching Fault Response, On/Off Control |
| Control Scheme | - | - | Primary-side | Primary-side |
| Duty Cycle | 64% | 64% | 64% | 64% |
| Duty Cycle Max | 66 % | 66 % | 66 % | - |
| Fault Protection | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit | Current Limiting, Over Load, Over Temperature, Over Voltage, Short Circuit |
| Input Supply Voltage Max | 265 VAC | 265 VAC | 265 VAC | - |
| Input Supply Voltage Min | 85 VAC | 85 VAC | 85 VAC | - |
| Internal Switch | - | - | Yes | Yes |
| Internal Switch S | Yes | Yes | Yes | Yes |
| Lifecycle Status | Active | Active | Obsolete | Obsolete |
| Max Input Voltage | - | - | 265 V | 265 V |
| Min Input Voltage | - | - | 85 V | 85 V |
| Moisture Sensitive | Yes | Yes | Yes | - |
| Number of Outputs | 1 | 1 | 1 | - |
| Operating Supply Current | 1.3 mA | 1.3 mA | 1.3 mA | - |
| Output Current | 12.5 uA | 12.5 uA | 12.5 uA | - |
| Output Isolation | Isolated | Isolated | Isolated | Isolated |
| Output Power | 30 W | 30 W | 30 W | - |
| Output Power Max Enclosed 230v | - | - | 21.0 W | 21.0 W |
| Output Power Max Enclosed Univ | - | - | 15.0 W | 15.0 W |
| Output Power Max Open Frame 230v | - | - | 48.0 W | 48.0 W |
| Output Power Max Open Frame Univ | - | - | 37.0 W | 37.0 W |
| Output Voltage | 50 V | 50 V | 50 V | - |
| Over Temperature Response | - | - | Hysteretic, Latch Off | Hysteretic, Latch Off |
| Package | 12-BESOP (0.350", 8.89mm Width), 11 Leads, Exposed Pad | 12-ESOP | eSOP-12B | eSOP-12B |
| Power Watts | 48 W | 48 W | 48 W | 48 W |
| Product Family | - | - | LinkSwitch-HP | LinkSwitch-HP |
| Product Type | - | - | IC | IC |
| Protection Features | - | - | Overtemperature, Output Overvoltage, Output Short Circuit, Output Open Loop, Output Overload, Line-compensated Overload | Overtemperature, Output Overvoltage, Output Short Circuit, Output Open Loop, Output Overload, Line-compensated Overload |
| Secondary Response | - | - | Auto-restart | Auto-restart |
| Series | LNK6xx | LNK6xx | LNK6xx | LinkSwitch™-HP |
| Supplier Device Package | 12-ESOP | 12-ESOP | 12-ESOP | 12-ESOP |
| Switching Frequency | 120kHz ~ 136kHz | 120kHz ~ 136kHz | 120kHz ~ 136kHz | 120kHz ~ 136kHz |
| Switching Frequency Max | - | - | 136 kHz | 136 kHz |
| Switching Frequency Min | - | - | 120 kHz | 120 kHz |
| Topology | Flyback | Flyback | Flyback | Flyback |
| Tradename | LinkSwitch-HP | LinkSwitch-HP | LinkSwitch-HP | - |
| Type | Off Line Converter | Off Line Converter | Off Line Converter | - |
| Voltage Breakdown | 725V | 650V | - | - |
| Request Quote | Request Quote | Request Quote | Request Quote |
Base Numbers
MPN counts describe each base number’s catalog coverage; they are not a series total.
| Base Number | Description | Variants | Action |
|---|---|---|---|
| LNK6666K | LNK6666K variants from Power Integrations | 2 MPNs | View Details |
| LNK6776K | LNK6776K variants from Power Integrations | 2 MPNs | View Details |
Technical Specifications
Select LinkSwitch-HP by primary-side regulation, LNK666x/LNK676x/LNK677x distinctions and programmed shutdown behavior.
Design and ordering considerations
LinkSwitch-HP Series Applications
Frequently Asked Questions
Common technical questions about the LinkSwitch-HP series.