LinkSwitch-CV: Constant-Voltage Regulation without an Optocoupler | Power Integrations
Review LinkSwitch-CV feedback architecture and load requirements for primary-side constant-voltage supplies.
LinkSwitch-CV: Constant-Voltage Regulation without an Optocoupler
Review LinkSwitch-CV feedback architecture and load requirements for primary-side constant-voltage supplies.
LinkSwitch-CV focuses on primary-side constant-voltage regulation, eliminating the optocoupler and secondary CV-control circuitry in the intended implementation. That architecture affects how the supply senses and regulates its output.
Select this family around the voltage tolerance and load range of the equipment. A CV designation should not be interpreted as a complete constant-current charging profile; overload protection and normal current regulation serve different purposes.
The manufacturer lists distinct enclosed and open-frame power capabilities. Compare the exact device and package under the relevant input conditions, and retain the transformer and feedback design when reviewing a board-level substitute.
Key Features
- Control objectiveConstant voltage
- Feedback arrangementPrimary-side regulation
- Replacement scopeTransformer, feedback and thermal implementation
Target Applications
- Constant-voltage auxiliary supplies
Compare LinkSwitch-CV Variants
Comparison of 6 selected variants from Power Integrations
| Parameter | LNK626DG-TL | LNK625DG-TL | LNK623DG-TL | LNK626DG | LNK625DG | LNK623DG |
|---|---|---|---|---|---|---|
| Package / Case | 8-SOIC (0.154", 3.90mm Width), 7 Leads | 8-SOIC (0.154", 3.90mm Width), 7 Leads | 8-SOIC (0.154", 3.90mm Width), 7 Leads | SO-8C | SO-8C | SO-8C |
| Max Operating Temp | - | - | - | 150 °C | 150 °C | 150 °C |
| Min Operating Temp | - | - | - | -40 °C | -40 °C | -40 °C |
| Operating Temperature | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) | -40°C ~ 150°C (TJ) |
| Breakdown Voltage | - | - | - | 725 V | 725 V | 725 V |
| Control Features | - | - | - | Frequency Jittering, Auto-Restart/Latching Fault Response, On/Off Control | Frequency Jittering, Auto-Restart/Latching Fault Response, On/Off Control | Frequency Jittering, Auto-Restart/Latching Fault Response, On/Off Control |
| Control Scheme | - | - | - | Primary-side | Primary-side | Primary-side |
| Current Pmpp | - | - | - | 520 uA | 480 uA | 440 uA |
| Duty Cycle | 54% | 54% | 54% | 54% | 54% | 54% |
| Duty Cycle Max | - | 54 % | 54 % | 54 % | 54 % | 54 % |
| Fault Protection | Current Limiting, Open Loop, Over Temperature, Short Circuit | Current Limiting, Open Loop, Over Temperature, Short Circuit | Current Limiting, Open Loop, Over Temperature, Short Circuit | Current Limiting, Open Loop, Over Temperature, Short Circuit | Current Limiting, Open Loop, Over Temperature, Short Circuit | Current Limiting, Open Loop, Over Temperature, Short Circuit |
| Input Supply Voltage Max | - | - | - | 265 VAC | 265 VAC | 265 VAC |
| Input Supply Voltage Min | - | - | - | 85 VAC | 85 VAC | 85 VAC |
| Internal Switch | - | - | - | Yes | Yes | Yes |
| Internal Switch S | Yes | Yes | Yes | Yes | Yes | Yes |
| Lifecycle Status | Active | Active | Active | Obsolete | Obsolete | Obsolete |
| Max Input Voltage | - | - | - | 265 V | 265 V | 265 V |
| Maximum Operating Temperature C | - | + 150 | + 150 | + 150 | + 150 | + 150 |
| Min Input Voltage | - | - | - | 85 V | 85 V | 85 V |
| Minimum Operating Temperature C | - | - 40 | - 40 | - 40 | - 40 | - 40 |
| Number of Outputs | - | 3 Output | 1 Output | 3 Output | 3 Output | 3 Output |
| Output Isolation | Isolated | Isolated | Isolated | Isolated | Isolated | Isolated |
| Output Power | - | 8 W | 6 W | 8.5 W | 8 W | 6 W |
| Output Power Max Enclosed 230v | - | - | - | 10.5 W | 8.0 W | 6.5 W |
| Output Power Max Enclosed Univ | - | - | - | 8.5 W | 6.5 W | 5.0 W |
| Output Power Max Open Frame 230v | - | - | - | 17.0 W | 13.5 W | 9.0 W |
| Output Power Max Open Frame Univ | - | - | - | 10.0 W | 8.0 W | 6.0 W |
| Output Profile | - | - | - | CV | CV | CV |
| Over Temperature Response | - | - | - | Hysteretic | Hysteretic | Hysteretic |
| Package | 8-SOIC | 8-SOIC | SO8C | SO-8C | SO-8C | SO-8C |
| Power Watts | 17 W | 13.5 W | 9 W | 17 W | 13.5 W | 9 W |
| Product Family | - | - | - | LinkSwitch-CV | LinkSwitch-CV | LinkSwitch-CV |
| Product Type | - | - | - | IC | IC | IC |
| Protection Features | - | - | - | Overtemperature, Output Short Circuit, Output Open Loop | Overtemperature, Output Short Circuit, Output Open Loop | Overtemperature, Output Short Circuit, Output Open Loop |
| Secondary Response | - | - | - | Auto-restart | Auto-restart | Auto-restart |
| Series | LNK6x | LNK6 | LNK6 | LNK6 | LNK6 | LNK6 |
| Supplier Device Package | SO-8C | SO-8C | SO-8C | SO-8C | SO-8C | SO-8C |
| Switching Frequency | 100kHz | 100kHz | 100kHz | 100kHz | 100kHz | 100kHz |
| Topology | Flyback | Flyback | Flyback | Flyback, Tapped Buck | Flyback, Tapped Buck | Flyback, Tapped Buck |
| Tradename | LinkSwitch-CV | LinkSwitch-CV | LinkSwitch-CV | LinkSwitch-CV | LinkSwitch-CV | LinkSwitch-CV |
| Unit Weight | 0.008113 oz | 0.010229 oz | 0.007055 oz | 0.010512 oz | 0.303356 oz | 0.035274 oz |
| Voltage Breakdown | 725V | 725V | 725V | - | - | - |
| Datasheet | - | - | - | |||
| Request Quote | Request Quote | Request Quote | Request Quote | Request Quote | Request Quote |
Base Numbers
MPN counts describe each base number’s catalog coverage; they are not a series total.
| Base Number | Description | Variants | Action |
|---|---|---|---|
| LNK623DG | LNK623DG variants from Power Integrations | 2 MPNs | View Details |
| LNK625DG | LNK625DG variants from Power Integrations | 2 MPNs | View Details |
| LNK626DG | LNK626DG variants from Power Integrations | 2 MPNs | View Details |
Technical Specifications
Review LinkSwitch-CV feedback architecture and load requirements for primary-side constant-voltage supplies.
Design and ordering considerations
LinkSwitch-CV Series Applications
Frequently Asked Questions
Common technical questions about the LinkSwitch-CV series.