1SP0335 Railway Drivers for 3.3–6.5 kV IGBTs | Power Integrations
In the 1SP0335 railway assembly the driver mounts on the IGBT and the ISO5125R supply mounts nearby. The driver is matched to the power module, while the separate supply is selected for the insulation required at that position in the inverter.
Specifying the supply for a railway inverter stack
In the 1SP0335 railway assembly the driver mounts on the IGBT and the ISO5125R supply mounts nearby. The driver is matched to the power module, while the separate supply is selected for the insulation required at that position in the inverter.
The supported module family spans 3.3 to 6.5 kV blocking voltage with 10.2 kV module isolation. A V master accepts Versatile Link and an S master accepts ST fiber. The D peripheral receives the command and secondary supplies through the group bus.
For vehicle qualification records, the family lists IEC 61373 shock and vibration compliance, PCB bend resistance and EN 50121-3-2 EMC qualification. Tie those records to the selected board and keep the power-supply specification with the same switch assembly.
Key Features
- Supply familyExternal ISO5125R
- Mechanical environmentIEC 61373 shock and vibration
Target Applications
- High-voltage railway converters with modular isolated gate supplies
Compare 1SP0335 Railway Variants
Comparison of 8 selected variants from Power Integrations
| Parameter | 1SP0335V2M1R-MBN1500FH45F-H | 1SP0335V2M1R-CM900HG-130X | 1SP0335V2M1R-CM600HG-130X | 1SP0335V2M1R-CM1500HG-90X | 1SP0335S2M1R-MBN1500FH45F-H | 1SP0335S2M1R-CM900HG-130X | 1SP0335S2M1R-CM600HG-130X | 1SP0335S2M1R-CM1500HG-90X |
|---|---|---|---|---|---|---|---|---|
| Connection Type to Igbt | Direct | Direct | Direct | Direct | Direct | Direct | Direct | Direct |
| Driving Mode | Direct-Independent | Direct-Independent | Direct-Independent | Direct-Independent | Direct-Independent | Direct-Independent | Direct-Independent | Direct-Independent |
| Gate Turn Off Voltage | --10.0 V | --10.0 V | --10.0 V | --10.0 V | --10.0 V | --10.0 V | --10.0 V | --10.0 V |
| Gate Turn on Voltage | +15.0 V | +15.0 V | +15.0 V | +15.0 V | +15.0 V | +15.0 V | +15.0 V | +15.0 V |
| Igbt Manufacturer | Hitachi | Mitsubishi | Mitsubishi | Mitsubishi | Hitachi | Mitsubishi | Mitsubishi | Mitsubishi |
| Igbt Voltage Class | 4500 V | 6500 V | 6500 V | 4500 V | 4500 V | 6500 V | 6500 V | 4500 V |
| Interface Type | Fiber Optic | Fiber Optic | Fiber Optic | Fiber Optic | Fiber Optic | Fiber Optic | Fiber Optic | Fiber Optic |
| Isolation Type | Basic | Basic | Basic | Basic | Basic | Basic | Basic | Basic |
| Main Peripheral | Main | Main | Main | Main | Main | Main | Main | Main |
| Max Gate Peak Current | +35 A | +35 A | +35 A | +35 A | +35 A | +35 A | +35 A | +35 A |
| Max Switching Frequency | 10.0 kHz | 10.0 kHz | 10.0 kHz | 10.0 kHz | 10.0 kHz | 10.0 kHz | 10.0 kHz | 10.0 kHz |
| Number of Channels | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 |
| Paralleling Support | Yes | Yes | Yes | Yes | Yes | Yes | Yes | Yes |
| Power Output Channel Max | 1.6 W | 1.6 W | 1.6 W | 1.6 W | 1.6 W | 1.6 W | 1.6 W | 1.6 W |
| Product Family | 1SP0335 Railway | 1SP0335 Railway | 1SP0335 Railway | 1SP0335 Railway | 1SP0335 Railway | 1SP0335 Railway | 1SP0335 Railway | 1SP0335 Railway |
| Protection Features | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) | Dynamic Adv Active Clamping, Over-voltage, Short Circuit, UVLO(Sec-side) |
| Railway Grade | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) | High-Ruggedness Connectors, PCB Bend-Resistance, Shock & Vibration Compliance (IEC 61373), Environmental Compliance (IEC 60068-2-xx), EMC Qualification (EN 50121-3-2 & IEC 61000-4-x) |
| Supported Module S | CM1500HG-90X | CM900HG-130X | CM600HG-130X | CM1500HG-90X | CM1500HG-90X | CM900HG-130X | CM600HG-130X | CM1500HG-90X |
| Supported Module Type | IGBT | IGBT | IGBT | IGBT | IGBT | IGBT | IGBT | IGBT |
| Supported Topologies | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped | 2-level Voltage Source, 3-level NP-Clamped - Type 1, 3-level NP-Clamped - Type 2, Multi-Level NP-Clamped |
| Technology | SCALE-2 | SCALE-2 | SCALE-2 | SCALE-2 | SCALE-2 | SCALE-2 | SCALE-2 | SCALE-2 |
| Voltage Dc Link Off State 60s | 3550 V | 3550 V | 3550 V | 3550 V | 3550 V | 3550 V | 3550 V | 3550 V |
| Request Quote | Request Quote | Request Quote | Request Quote | Request Quote | Request Quote | Request Quote | Request Quote |
Base Numbers
MPN counts describe each base number’s catalog coverage; they are not a series total.
| Base Number | Description | Variants | Status | Action |
|---|---|---|---|---|
| 1SP0335S2M1 | 1SP0335S2M1 variants from Power Integrations | 4 MPNs | Active | View Details |
| 1SP0335V2M1 | 1SP0335V2M1 variants from Power Integrations | 4 MPNs | Active | View Details |
Technical Specifications
Specifying the supply for a railway inverter stack
Frequently Asked Questions
Common technical questions about the 1SP0335 Railway series.