Skip to main content

Yageo KEMET RL0805FR

RL0805FR variants from Yageo KEMET

RL0805FR Datasheet

Variants

36

Mfr

Yageo

Lifecycle

Active

RL0805FR Overview

What changes between part numbers, and what to check before you lock the BOM — Passive Components.

RL0805FR is a Yageo order-code family — not a single orderable MPN. This page lists 36 variants that share the same core device but differ in suffix fields (package, grade, reel/tube, electrical bin, etc.). Pick the exact full part number; substituting within the family without checking the datasheet often causes assembly or spec mismatches.

Fixed Resistor, Metal Glaze/thick Film, 0.125W, 0.012ohm, 1% +/-Tol, -1500,1500ppm/Cel, 0805 Other listed variants describe: RES 0.015 OHM 1% 1/8W 0805; RES 0.01 OHM 1% 1/8W 0805.

Suffix examples in this family: 070R012L, 070R015L, 070R01L, 070R024L, 070R025L, 070R02L, 070R043L, 070R04L. The characters after the base number usually encode package, temperature, or performance grade — compare the variant table column-by-column rather than assuming pin-compatible drops-in.

Example MPNs: RL0805FR-070R012L, RL0805FR-070R015L, RL0805FR-070R01L, RL0805FR-070R024L, RL0805FR-070R025L, RL0805FR-070R02L.

Key Features

  • Lifecycle mix: ActiveConfirm lifecycle on the exact MPN, not just the base number prefix.
  • 36 distinct suffix patternsExamples: 070R012L, 070R015L, 070R01L, 070R024L, 070R025L (+31 more). Decode suffix meaning in the ordering notes under the variant table.

Target Applications

  • Passive Components — design-in and field replacement
  • BOM scrub where only the base prefix is known but suffix is TBD
  • Second-source checks when the original MPN is constrained

Ordering Variants

Compare 36 RL0805FR part numbers by package, electrical parameters, lifecycle, and availability. Use RFQ for stock and lead-time confirmation.

Part NumberDescriptionManufacturerLifecycleRoHSAvailabilityAction
RL0805FR-070R012LFixed Resistor, Metal Glaze/thick Film, 0.125W, 0.012ohm, 1% +/-Tol, -1500,1500ppm/Cel, 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R015LRES 0.015 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R01LRES 0.01 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R024LRes Thick Film 0805 0.024 Ohm 1% 0.125W(1/8W) ±1200ppm/°C Pad SMD Automotive T/RYageo KEMETActiveCompliantIn Stock
RL0805FR-070R025LRES 0.025 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R02LRES 0.02 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R043LRES 0.043 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R04LRES 0.04 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R05LRes Thick Film 0805 0.05 Ohm 1% 0.125W(1/8W) ±1000ppm/°C Pad SMD Automotive T/RYageo KEMETActiveCompliantIn Stock
RL0805FR-070R06LRES 0.06 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R12LRES 0.12 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R13LRES 0.13 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R15LRES 0.15 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R1LRES 0.1 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R22LRES 0.22 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R25LRES 0.25 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R27LFixed Resistor, Metal Glaze/thick Film, 0.125W, 0.27ohm, 1% +/-Tol, -600,600ppm/Cel, 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R2LRES 0.2 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R33LRES 0.33 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock
RL0805FR-070R36LRES 0.36 OHM 1% 1/8W 0805Yageo KEMETActiveCompliantIn Stock

Ordering Code Differences

How suffixes on RL0805FR map to package, grade, and reel options.

RL0805FR uses a shared prefix; characters after the prefix encode orderable options. Two lines with the same prefix are not drop-in replacements unless the differing columns match your need.

Suffixes seen here: 070R012L, 070R015L, 070R01L, 070R024L, 070R025L, 070R02L, 070R043L, 070R04L, 070R05L, 070R06L (+26 more).

Full MPN examples: RL0805FR-070R012L, RL0805FR-070R015L, RL0805FR-070R01L, RL0805FR-070R024L, RL0805FR-070R025L.

Tip: photograph or copy the reel label — reel diameter, QTY per reel, and moisture sensitivity level (MSL) are often suffix-driven and won't show in the schematic.

How to Choose the Right RL0805FR Passive Components

📦

Match the footprint first

Pull the exact package drawing for your MPN — base-number swaps fail most often at the footprint, not the schematic.

Electrical headroom

Compare voltage and current columns in the variant table. For RL0805FR, a suffix with lower voltage or current rating will not survive the same circuit without recalculation.

🌡️

Temp grade letter matters

Commercial (0–70 °C) and industrial (−40–85 °C+) suffixes look similar in the prefix — confirm ambient + self-heating, not just the first page of the datasheet.

🔢

Copy the full MPN

Do not BOM only "RL0805FR" — include the full suffix (e.g. 070R012L, 070R015L, 070R01L). RFQ with reel/tube preference and required date code.

Technical Specifications

Core parameters for RL0805FR product family

Identity

Base Model
RL0805FR
Manufacturer
Yageo
Listed Variants
36

Variant Parameters

Lifecycle Status
Active
RoHS Status
Compliant

Source RL0805FR with Octatronics

Request stock confirmation, lead time, date code, and pricing for all 36 ordering variants from Yageo. Our team supports active, EOL, and hard-to-find component sourcing.

  • Original manufacturer parts with traceability options
  • BOM upload and multi-line RFQ support
  • Package, grade, and compliance verification

Frequently Asked Questions

Common technical questions about the RL0805FR product family.

RL0805FR is a base / family code from Yageo. You order a full MPN such as RL0805FR-070R012L, RL0805FR-070R015L, RL0805FR-070R01L. The variant table lists 36 orderable lines with different suffixes.
Listed suffix fragments include: 070R012L, 070R015L, 070R01L, 070R024L, 070R025L, 070R02L. Typically they encode package (see Package column), temperature grade, and tape/reel option. Always decode on the Yageo datasheet ordering guide — do not guess from pattern alone.
Lifecycle values in our listing: Active. Status is per MPN suffix — one variant can be Active while another is NRND. Check PCN for your exact suffix before multi-year commitments.
Full manufacturer MPN (not just RL0805FR), quantity, needed date code, reel vs tube, and any compliance docs (CoC, RoHS, conflict minerals). If you only know the base prefix, include a photo of the existing label or reel.
Use the datasheet link in the page header. Cross-check electrical curves (SOA, saturation voltage, etc.) against your operating point — the table summarizes order codes, not every graph in the PDF.