Skip to main content

TDK MLF2012A

MLF2012A variants from TDK

MLF2012A Datasheet

Variants

14

Mfr

TDK

Lifecycle

Active

MLF2012A Overview

What changes between part numbers, and what to check before you lock the BOM — Passive Components.

Key Features

  • Lifecycle mix: ActiveConfirm lifecycle on the exact MPN, not just the base number prefix.
  • 14 distinct suffix patternsExamples: 1R0JT000, 1R0KT000, 1R2KT000, 1R5KT000, 1R8KT000 (+9 more). Decode suffix meaning in the ordering notes under the variant table.

Target Applications

  • Passive Components — design-in and field replacement
  • BOM scrub where only the base prefix is known but suffix is TBD
  • Second-source checks when the original MPN is constrained

Ordering Variants

Compare 14 MLF2012A part numbers by package, electrical parameters, lifecycle, and availability. Use RFQ for stock and lead-time confirmation.

Part NumberDescriptionManufacturerLifecycleRoHSAvailabilityAction
MLF2012A1R0JT000FIXED IND 1UH 80MA 300 MOHM SMDTDKActiveCompliantIn Stock
MLF2012A1R0KT000FIXED IND 1UH 80MA 300 MOHM SMDTDKActiveCompliantIn Stock
MLF2012A1R2KT000FIXED IND 1.2UH 80MA 350MOHM SMDTDKActiveCompliantIn Stock
MLF2012A1R5KT000FIXED IND 1.5UH 80MA 400MOHM SMDTDKActiveCompliantIn Stock
MLF2012A1R8KT000FIXED IND 1.8UH 80MA 450MOHM SMDTDKActiveCompliantIn Stock
MLF2012A2R2JT000FIXED IND 2.2UH 50MA 500MOHM SMDTDKActiveCompliantIn Stock
MLF2012A2R2KT000FIXED IND 2.2UH 50MA 500MOHM SMDTDKActiveCompliantIn Stock
MLF2012A2R7JT000FIXED IND 2.7UH 50MA 550MOHM SMDTDKActiveCompliantIn Stock
MLF2012A2R7KT000FIXED IND 2.7UH 50MA 550MOHM SMDTDKActiveCompliantIn Stock
MLF2012A3R3JT000FIXED IND 3.3UH 50MA 600MOHM SMDTDKActiveCompliantIn Stock
MLF2012A3R3KT000FIXED IND 3.3UH 50MA 600MOHM SMDTDKActiveCompliantIn Stock
MLF2012A4R7JT000FIXED IND 4.7UH 30MA 700MOHM SMDTDKActiveCompliantIn Stock
MLF2012A4R7KT000FIXED IND 4.7UH 30MA 700MOHM SMDTDKActiveCompliantIn Stock
MLF2012A4R7KTD25FIXED IND 4.7UH 30MA 700MOHM SMDTDKActiveCompliantIn Stock

Ordering Code Differences

How suffixes on MLF2012A map to package, grade, and reel options.

How to Choose the Right MLF2012A Passive Components

📦

Match the footprint first

Pull the exact package drawing for your MPN — base-number swaps fail most often at the footprint, not the schematic.

Electrical headroom

Compare voltage and current columns in the variant table. For MLF2012A, a suffix with lower voltage or current rating will not survive the same circuit without recalculation.

🌡️

Temp grade letter matters

Commercial (0–70 °C) and industrial (−40–85 °C+) suffixes look similar in the prefix — confirm ambient + self-heating, not just the first page of the datasheet.

🔢

Copy the full MPN

Do not BOM only "MLF2012A" — include the full suffix (e.g. 1R0JT000, 1R0KT000, 1R2KT000). RFQ with reel/tube preference and required date code.

Technical Specifications

Core parameters for MLF2012A product family

Identity

Base Model
MLF2012A
Manufacturer
TDK
Listed Variants
14

Variant Parameters

Lifecycle Status
Active
RoHS Status
Compliant

Source MLF2012A with Octatronics

Request stock confirmation, lead time, date code, and pricing for all 14 ordering variants from TDK. Our team supports active, EOL, and hard-to-find component sourcing.

  • Original manufacturer parts with traceability options
  • BOM upload and multi-line RFQ support
  • Package, grade, and compliance verification

Frequently Asked Questions

Common technical questions about the MLF2012A product family.

MLF2012A is a base / family code from TDK. You order a full MPN such as MLF2012A1R0JT000, MLF2012A1R0KT000, MLF2012A1R2KT000. The variant table lists 14 orderable lines with different suffixes.
Listed suffix fragments include: 1R0JT000, 1R0KT000, 1R2KT000, 1R5KT000, 1R8KT000, 2R2JT000. Typically they encode package (see Package column), temperature grade, and tape/reel option. Always decode on the TDK datasheet ordering guide — do not guess from pattern alone.
Lifecycle values in our listing: Active. Status is per MPN suffix — one variant can be Active while another is NRND. Check PCN for your exact suffix before multi-year commitments.
Full manufacturer MPN (not just MLF2012A), quantity, needed date code, reel vs tube, and any compliance docs (CoC, RoHS, conflict minerals). If you only know the base prefix, include a photo of the existing label or reel.
Use the datasheet link in the page header. Cross-check electrical curves (SOA, saturation voltage, etc.) against your operating point — the table summarizes order codes, not every graph in the PDF.